Description:
The above video clip is of a combination IR and Airborne UT done on a pillow block bearing of a printing press.
During the IR part of this video clip you will also hear the UT sound superimposed within the IR video.
Doing a combination IR & UT survey on your rotating machinery and steam trap system greatly increases your ability to diagnose problems.
As Predictive Maintenance Inspectors, we know that Multi-Technology Diagnostics is needed sometimes to better quantify equipment problems.
Note: The above Video Clip is in Windows Media Player format.
Info Submitted By:
Sonny James
Level III Certified Infrared Thermographer
Thermal Diagnostics Limited
Tel/Fax: (868)-657-6572